AC + DC Current Sources
Current generators of the GIS2k Series are static sources of AC and DC constant current. Models up to 5000A/200kVA for continuous or pulse operation make up one of the largest ranges of 1- and 3-phase system available today on the market.
Current generators of the GIS2k Series supply a very stable AC current at a variable frequency up to 2500Hz or a DC current. Up to two current ranges per unit are provided, with manual or automatic selection. Equipped with a modern and easy to use front panel interface with a large LCD display, the controllers of the GIS2k Series offer advanced capabilities for current test applications.
Standard low power units are built into 19” racks or table cases. High power units are built into 19” cabinets on wheels.
Ideally suited for lab applications (R&D), the GIS2k Series finds a great role in final product testing. Remote control is via the standard isolated RS232 and RS485, or optional USB, LAN, and Fiber Optic Interfaces. Analog inputs (Booster inputs) are available as well and allow the units to be used as current amplifiers using external analog signals. They can for example be used as amplifier to reproduce arbitrary current waveforms. In addition, eight Digital inputs/outputs allow finally the GIS2k Series to be perfectly integrated in manufacturing lines.
Specially developed for the test of circuit breakers, the GIS2k Series is equipped with a sequencer and timer, allowing to set current and test time and measuring accurately the trip time with a resolution up to 1ms. Different modes like ramp, drop out and loop are available in order to create test program and sequences following norms or custom manufacturer procedures.
Front Panel Controls
The sealed and splash proof membrane keypad of the GI-IS Series holds up well in harsh production environments and make for easy operator control. The large back-lit LCD display provides large readout of settings and test results for the operator to see. Test sequences can be programmed from the front panel as needed and locked down to prevent unauthorized changes. Test results include trip current levels and trip duration with msec resolution.
Web Browser Interface
In addition to front panel operation, a standard embedded web server function allows remote operation
of the GI2k Current Source from a web browser Interface when using the Ethernet interface.
- Output Current: up to 5000A
- Output Frequency: DC, 10-800Hz (internal Ctrlr) DC, 1500Hz (external Ctrlr, optional 2500Hz)
- Single and Three-Phase Systems
- Possibility of Paralleling for higher current
- Continuous or Pulse Mode Operation
- Up to 2 Output Current Ranges
- Integrated Timer and Sequencer with up to 30 steps
- Measurement of Trip Time for Fuse and CB test
- Ramp, Drop-out, Loop Modes
- Easy Maintenance and Calibration
- Access to PID Regulation Parameters
- >Web Browser Control Interface via LAN
- Customized Units on request
- Thermal and magnetic tests of switches, breakers,relays or fuses with trip-time measurements
- Heating tests of electrical contacts
- Tests of coils and transformers
- Tests and calibration of measurement instruments
Available Configurations
Output Voltage (V) | Output Power (kW) | Output Current (A) |
---|---|---|
5-9 | 2 | 500 |
5 | 1000 | |
10 | 2000 | |
25 | 5000 | |
10-19 | 2 | 200 |
5 | 500 | |
10 | 1000 | |
25 | 2000 | |
20-29 | 2 | 100 |
5 | 250 | |
10 | 500 | |
20 | 1000 | |
30 | 1500 | |
40 | 2500 | |
30-49 | 2 | 83 |
5 | 166 | |
10 | 333 | |
20 | 666 | |
30 | 1000 | |
40 | 1330 | |
50-99 | 5 | 100 |
10 | 200 | |
20 | 400 | |
30 | 600 | |
40 | 800 | |
60 | 1200 | |
80 | 1600 | |
100-199 | 5 | 50 |
10 | 100 | |
20 | 200 | |
30 | 300 | |
40 | 400 | |
60 | 600 | |
80 | 800 |
Option | Description |
---|---|
/M-GI-SW | Software including arbitrary waveforms for single phase unit |
/M3-GI-SW | Software including arbitrary waveforms for 3 phase system |
/PID | PID software, access to PID-regulation parameters |
/Rack | 19” Rack instead of cabinet (available up to 5kVA) |
/3-Rack | 19” Rack with connections for 3 phase systems |
/Wheels | Cabinet with wheels max weight 800kg |
/LAN | LAN interface |
/USB | USB interface |
/FO | Fiber Optic interface |
/ROUT | Rear output connections |
/FOUT | Front output connections |
/SOUT | Special output connections |
/TCase | Tablet case |
/Axxxx | Special output current range (P.E. A8000 = 8000A f.s.) |
/MRange | Manual Switching of current range |
/ARange | Automatic Switching of current range |
/IP | Special IP protection |
/ATE Unit | Without Front panel control and display, for system integration |
/DC-CTRL | DC control mode of output (0-10V) |