PRECISION AC & DC POWER ANALYZERS
The M2000 Series consists of selection of one to four channel, precision power analyzers geared toward AC and DC power measurement applications.
Designed using state-of-the-art Digital Signal Processing, this modular power analyzer supports up four measurement cards using either internal or external current shunts. Each card has separate, fully synchronized, 24-bit high-speed data acquisition hardware that conditions and captures voltage and current input signals and processes data into a broad range of measurements.
For single-phase applications, the M2001 is all you need. For multi-phase power applications, the M2003 models support Delta and Wye AC power configurations to measure all phase voltages, currents and power.
Designed using state-of-the-art Digital Signal Processing, this modular power analyzer supports up four measurement cards using either internal or external current shunts. Each card has separate, fully synchronized, 24-bit high-speed data acquisition hardware that conditions and captures voltage and current input signals and processes data into a broad range of measurements.
Despite its breath of functions and features, the M2000 is simple to operate and provides an array of data display capabilities, taking full advantage of its high resolution color graphics display to present results in an optimal, easy to read and understand format.
AC Voltage Range (Vac) is 1000Vrms / 1850Vpk. DC Voltage Range (Vdc) is 1000Vdc. The internal shunt is rated at 20Arms / 150Apk for D type and 30Arms / 200Apk for H type plug-in cards. An external shunt may be used for higher current and power level requirements using the X type plug-in cards. For single-phase applications, the M2001D model is all you need. For multi-phase power applications, the M2003 models support Delta and Wye AC power configurations to measure all phase voltages, currents, power, VA, VAR, Vthd, Ithd and Harmonics up to 500th.
Standard remote control interface are USB, LAN and RS232.
- Affordable Accuracy, Bandwidth and Ease of Use
- Large Color Touch Screen Operation
- Multi-Channel Configurations
- Internal Shunt or External Current Transducer Channel Cards
- Extensive Measurement Functions to 1.25MHz:
- Vac, Vdc, Vrms, Vac+dc, Iac, Idc, Irms, Iac+dc
- Watts, VA, VAR, PF, CF
- Voltage & Current Harmonics, Vthd, Ithd
- Multiple Virtual Power Analyzer Configurations
- Numeric and Graphical Displays
- Energy Star / IEC62301 Compliant Standby Power Measurement mode
- Ultra-quiet Fanless Operation
- Bench Use or 4U Height 19” Rack Mount
Large Color Touch Screen Operation
Front panel operation of the M2000 Power Analyzer is accomplished completely using its large touch-sensitive display. There are no buttons or dials to distract from the rich data displays provided to the user.
Power Measurements
The power data screen displays Frequency, Voltage, Current, Crest Factor, Power, VA, VAR and Power Factor data for any selected channel or group of channels. Up to three different channel groups can exist in a single M2000 power analyzer.
Harmonics Analysis
Harmonic Analysis is performed on each input of each channel configured to do so. There is no restriction on the number of channels configured for harmonic analysis other than max. available inputs (8). Up to 500 harmonics per channel can be analyzed.
Scope View Mode
The scope view display time domain information similar to a digital storage scope. Up to six signal can be displayed at once, each one having its own vertical scaling, offset and color. Common scope functions like timebase trigger level and trigger offset are user settable as well.
Vector View Mode
A polar chart graphically displays the fundamental voltage and current vectors for the selected channel or channel group. For multi-phase groups, the inter-phase voltages and non-measured neutral phase vectors are displayed. The user can enable the display of and select the color of each vector up to a maximum of 10.
Standby Power Measurements
Designing products with very low standby current is important to minimize waste. The standby power measurement mode of the M1001 allows certification to the ENERGY STAR / EN62301 standard.
Product Burn-in Data Logging
The M2000 features built in standby power testing in accordance to EN50564:2011 (replaces IEC62301) which can be started by the pressing the STBY POWER screen touch key.
Avionics & Defense Power Test
The high bandwidth and accuracy of the M2000 Series supports a wide range of defense and avionics measurement applications for 400Hz fixed frequency or 360Hz to 800Hz wild frequency electrical equipment. Special measurement modes are provided for common avionics power compliance test standards such as RTCA DO-160, Section 16 or Boeing 787B3-0147.
IEC 61000-3-2 & 61000-3-12 Harmonic Emissions Test
Products destined for Europe must meet Harmonics emissions limits as determined by harmonized standards IEC 61000-3-2 and IEC 61000-3-12. The M2000 can be used to check products during development for compliance so formal CE approval can be obtained more easily and less costly than finding problems later in the product development cycle.
Models
Model | No. V+I Channels | Voltage Range (Vac) | Voltage Range (Vdc) | Max. Current (Iac) | Max. Current (Idc) | Input Power | Height | Weight (Kg/Lbs) |
---|---|---|---|---|---|---|---|---|
M2001D | 1 | 1000 Vrms / 1850Vpk | 1000 Vdc | 20 Arms / 150 Apk | 20 Adc | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.2 / 7.0 |
M2001H | 1 | 1000 Vrms / 1850Vpk | 1000 Vdc | 30 Arms / 200 Apk | 30 Adc | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.2 / 7.0 |
M2001X | 1 | 1000 Vrms / 1850Vpk | 1000 Vdc | External Shunt or CT | External Shunt or CT | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.2 / 7.0 |
M2003D | 3 | 1000 Vrms / 1850Vpk | 1000 Vdc | 20 Arms / 150 Apk | 20 Adc | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.4 / 7.5 |
M2003H | 3 | 1000 Vrms / 1850Vpk | 1000 Vdc | 30 Arms / 200 Apk | 30 Adc | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.4 / 7.5 |
M2003X | 3 | 1000 Vrms / 1850Vpk | 1000 Vdc | External Shunt or CT | External Shunt or CT | 100 ~ 230Vac | 5.25" / 133 mm (3U) | 3.4 / 7.5 |
Measurements | Item | Specification | Unit |
---|---|---|---|
Voltage | Base Accuracy | 0.03% Rdg | Volts |
Resolution | 0.1V | Volts | |
Current | Base Accuracy | 0.03% Rdg | |
AC &DC Power | Range | V range * I range | Watts |
Accuracy | ± 0.01% Rdg | Watts | |
Frequency | Range | DC, 0.19 Hz ~ 80 kHz | Hz |
Accuracy | ± 0.01% | Hz | |
V/I Harmonics | Range | 1 ~ 500th | Volts, Amps |
Accuracy | 0.006% + (0.004% + 0.028% * F) / PF | Volts, Amps |