Programmable DC Power Supplies
Look no further for powerful yet cost effective DC power test solutions than the compact DCS Series programmable DC power supplies from Adaptive Power Systems. Designed using state-of-the-art Digital Signal Processing, these power supplies support a wide range DC tests with excellent performance and reliability. The DCS units are versatile power sources with a auto-ranging constant power V-I output profile that offers both higher voltage and high current from a single model.
Available in four power levels of 5kW , 10kW, 15kW or 30kW, there are several voltage range models up to 2000Vdc and 510Adc current per 3U chassis or 2000Vdc and 1000Adc per 4U chassis. Available with universal 208~480 Vac three phase AC input. (Power derated for 208Vac input to 60% of max.) Master/ Slave mode for series or parallel operation available for higher voltage and or power requirements.
The DCS Series of precision DC power Supplies uses state of the art field programmable logic array (FPGA) technology to implement a digital power conversion topology that combines high efficiency with a rich feature set and excellent specifications. This results in 16-bit resolution precision for both set points and measurements throughout.
Packaged in a compact, standard 19” rack mount chassis, these powerful functions are easily accessible through an easy to use, large color touch screen based user interface from the front panel or by sending commands over one of several available digital control interfaces. With 30kW in a 4U tall rack mount chassis, the DCS Series represents the highest available power density.
All DCS models are equipped with a flexible auto-ranging output stage which provides higher output voltage at lower output current, or higher output current at lower output voltage, always controlled by the adjustable power set value . Therefore, a wide range of applications can be covered by the use of just one DCS model. This also greatly reduces the need for 20 different voltage/current combination models as is typical for conventional DC power supplies.
The DCS Series power sources are reliable and cost effective solutions for all of your DC power design and test needs!
Features
- Output voltage ranges from 80 V up to 2000 V
- Constant Power Auto-ranging Voltage/Current profile
- Current: 30 A up to 1000 A, parallelable for higher current
- Output power 5, 10 or 15 kW per 3U chassis or 30kW per 4U chassis
- Parallel mode expandable up to 1920 kW
- High overall efficiency up to 95.5% saves on energy cost
- Three phase universal input voltage 208Vac~480Vac wide range
- Active Power Factor Corrected AC input
- Flexible, precisely regulated output power stages
- Various protection circuits (OVP, OCP, OPP, OTP)
- Intuitive TFT touch panel with display of settings, read-backs, status and notifications
- Remote sensing with automatic open sense detection
- Galvanically isolated analog interface and USB port
- Integrated function generator
- Photovoltaic array simulation, including EN 50530
- Internal resistance simulation and regulation
- Output Voltage Discharge circuit (Vout < 60 V in ≤ 10 s)
- Optional, digital, plug & play interfaces
- GPIB interface option available on 3U models only
- SCPI commands and ModBus RTU (optional: ModBus TCP) support
Common Specifications
- AC Input
- Input Voltage:
- HP models: Universal 208~480VLL ±10% 3ph
- Frequency: 45-66Hz
- Power Factor: > 0.99
- Input Voltage:
- DC Output
- Accuracy: < 0.1% of F.S.
- Load regulation 0-100%: < 0.05% of F.S.
- Line regulation ±10% ΔVac: < 0.02% of F.S.
- Response Time 10-100% load: < 2 msec
- Slew rate 10-90%: < 30 msec
- Overvoltage protection: Adjustable, 0~110% Vnom
- No load discharge time on DC off: 100% V to < 60 V, less than 10 sec
- DC Current
- Accuracy: < 0.2% of F.S.
- Load regulation 0-100% ΔVdc: < 0.15% of F.S.
- Line regulation ±10% ΔVac: < 0.05% of F.S.
- DC Power
- Accuracy: < 1.0% of F.S.
- Overvoltage category: 2
- Protection: OT, OVP, OCP, OPP, PF
- Insulation
- AC input to enclosure: 2500 Vdc
- AC input to DC output: 2500 Vdc
- DC output to enclosure (PE): Model specific. See model tables
- Parallel Operation: Master-slave, up to 32 units
- Regulatory Standards: EN 61010, EN 61000-6-2:2016-05 and IEC 61000-6-3:2011-09 Class B
- Environmental
- Pollution Degree: 2
- Protection Class: 1
- Cooling: Forced air, temperature controlled fans
- Temperature Operating: 0~50 °C / 32~122 °F
- Storage: -20~70 °C / -4~158 °F
- Relative humidity: < 80%, non-condensing
- Altitude Operating: < 2000 m (1.242 mi)
- Front Panel
- Display: Color Touch Screen Graphics LCD
- Controls: Dual Rotary Digital Encoders
- Output on/off: Push Button
- Digital Interfaces
- Internal: 1x USB type B for communication, 1x GPIB (optional)
- Interface Slot: 1x for retrofittable plug-in modules
- Analog Interfaces
- Internal: Built-in, 15 pole D-Sub (female), galvanically isolated
- Signal range: 0~5 V or 0~10 V (selectable)
- Inputs: V, I, P, R, remote control on-off, DC output on-off, resistance mode on-off
- Outputs: V, I, alarms, reference voltage, status
- Accuracy V / I / P / R: 0~10 V: < 0.2%, 0~5 V: < 0.4%
- Dimensions
- 3U Models: 19” x 5.25” x 26.4” / 483 x 133 x 670 mm
- 4U Models: 19” x 7” x 26.4” / 483 x 178 x 670 mm
DC Test Power
The DCS Series programmable Power Sources use state-of-the-art DSP technology to provide stable and accurate output, regardless of AC input line conditions. careful filtering and digital power controls ensure class leasing output noise levels at these power levels. The large TFT touch screen supports all user interactions with the help of just two rotary knobs. A decimal keypad pop-up allows direct entry of parameters as well. Both output setting and measurements can be displayed on the display in large fonts, visible from a distance if needed.
Telecom Power Converter Test and Burn-in
The wide operating range of the DCS power supplies, make possible by their auto-ranging output is ideal for testing modern DC/DC converters that can accept a wide range of DC input voltages. Since the same DCS model can support low voltage at high current as well as high voltage at low current, there is longer any need to oversize the DC supply used. This results in significant cost savings.
Battery Forming
With its high power density and programming battery charging profiles, the DCS series can be used for forming large batteries up to 1500Vdc. When combined with APS’s 6RL series of regenerative DC loads, a cost effective complete battery test system can be configured using the Master/Slave mode of both units.
Product Development and Test
With the ability to provide programmable over-voltage, over-current and over-power, the DCS power supply can safely be used to power up early prototypes without feat of losing time or money due to scarce prototype failure.
PV Inverter Testing
With models available to 1500Vdc output, a wide assortment of photo-voltaic inverters can be tested by replacing actual PV panels and light sources with a programmable DC power supply. The built-in function generator of the DCS can be used to simulate a wide range of PV characteristics including ISC, UOC, UMPP, IMPP and Irradiance.
Avionics Power
Capable of supporting 28Vdc and ±270Vdc (using 2 units in master/slave series), the DCS Series is a good choice for testing DC power avionics products as well.
5kW Model Comparison
Model | Power (W) | Max. Voltage (Vdc) | Max. Current (Adc) | Input Power | Height | Weight (Kg/Lbs) |
---|---|---|---|---|---|---|
DCS80-170HP | 5000 / (3000) | 80 | 170 | 208V ~ 480V - 3ø | 3U | 18 / 39.7 |
DCS200-70HP | 5000 / (3000) | 200 | 70 | 208V ~ 480V - 3ø | 3U | 18 / 39.7 |
DCS360-40HP | 5000 / (3000) | 360 | 40 | 208V ~ 480V - 3ø | 3U | 18 / 39.7 |
DCS500-30HP | 5000 / (3000) | 500 | 30 | 208V ~ 480V - 3ø | 3U | 18 / 39.7 |
DCS750-20HP | 5000 / (3000) | 750 | 20 | 208V ~ 480V - 3ø | 3U | 18 / 39.7 |
5kW Specifications
Model | DCS80-170HP | DCS200-70HP | DCS360-40HP | DCS500-30HP | DCS750-20HP |
---|---|---|---|---|---|
Voltage Range | 0~80 V | 0~200 V | 0~360 V | 0~500 V | 0~750 V |
Current Range | 0…170 A | 0…70 A | 0…40 A | 0…30 A | 0…20 A |
CP V-I Range | 29.4V@170A ~ 80V@62.5A | 71.4V@70A ~ 200V@25A | 125V@40A ~ 360V@13.9A | 166.7V@30A ~ 500V@10A | 250V@20A ~ 750V@6.7A |
Voltage Ripple | <200 mVpp <16 mVrms | <300 mVpp <40 mVrms | <550mVpp <65mVrms | <350mVpp <70mVrms | <800mVpp <200mVrms |
Current Ripple | <80 mArms | <22 mArms | <18 mArms | <16 mArms | <16 mArms |
Insulation -DC to PE | ±600 Vdc | ±1000 Vdc | ±1000 Vdc | ±1500 Vdc | ±1500 Vdc |
Insulation +DC to PE | +600 Vdc | +1000 Vdc | +1000 Vdc | +2000 Vdc | +2000 Vdc |
Power Range | 0~5000 W / (3000 W) | 0~5000 W / (3000 W) | 0~5000 W / (3000 W) | 0~5000 W / (3000 W) | 0~5000 W / (3000 W) |
Efficiency | 94.5% | 94.5% | 95.5% | 95.5% | 95.5% |
10kW Model Comparison
Model | Power (VA/W) | Max. Voltage (Vdc) | Max. Current (Adc) | Input Power | Height | Weight (Kg/Lbs) |
---|---|---|---|---|---|---|
DCS80-340HP | 10000 / (6000) | 80 | 340 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS200-140HP | 10000 / (6000) | 200 | 140 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS360-80HP | 10000 / (6000) | 360 | 80 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS500-60HP | 10000 / (6000) | 500 | 60 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS750-40Hp | 10000 / (6000) | 750 | 40 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS1000-30HP | 10000 / (6000) | 1000 | 30 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
DCS1500-20HP | 10000 / (6000) | 1500 | 20 | 208V ~ 480V - 3ø | 3U | 25 / 55.1 |
10kW Specifications
Model | DCS80-340HP | DCS200-140HP | DCS360-80HP | DCS500-60HP | DCS750-40HP | DCS1000-30HP | DCS1500-20HP |
---|---|---|---|---|---|---|---|
Voltage Range | 0~80 V | 0~200 V | 0~360 V | 0~500 V | 0~750 V | 0~1000 V | 0~1500 V |
Current Range | 0…340 A | 0…140 A | 0~80 A | 0~60 A | 0~40 A | 0~30 A | 0~20 A |
CP V-I Range | 29.4V@340A ~ 80V@125A | 71.4V@140A ~ 200V@50A | 125V@80A ~ 360V@27.8A | 166.7V@60A ~ 500V@20A | 250V@40A ~ 750V@13.3A | 333.3V@30A ~ 1000V@10A | 500V@20A ~ 1500V@6.7A |
Voltage Ripple | <100mVpp <10mVrms | <300mVpp <40mVrms | <320mVpp <55mVrms | <350mVpp <70mVrms | <800mVpp <200mVrms | <1000mVpp <200mVrms | <2000mVpp <400mVrms |
Current Ripple | <160 mArms | <44 mArms | <35mArms | <32mArms | <32mArms | <22mArms | <22mArms |
Insulation -DC to PE | ±600 Vdc | ±1000 Vdc | ±1000V DC | ±1500 V DC | ±1500 V DC | ±1500 V DC | ±1500 V DC |
Insulation +DC to PE | +600 Vdc | +1000 Vdc | +1000 Vdc | +2000 V DC | +2000 V DC | +2000 V DC | +2000 V DC |
Power Range | 0~10000 W (6000 W) | 0~10000 W (6000 W) | 0~10000 W (6000 W) | 0~10000 W (6000 W) | 0~10000 W (6000 W) | 0~10000 W (6000 W) | 0~10000 W (6000 W) |
Efficiency | 94.5% | 94.5% | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% |
15kW Model Comparison
Model | Power (VA/W) | Max. Voltage (Vdc) | Max. Current (Adc) | Input Power | Height | Weight (Kg/Lbs) |
---|---|---|---|---|---|---|
DCS80-510HP | 15000 / (9000) | 80 | 510 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS200-210HP | 15000 / (9000) | 200 | 140 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS360-120HP | 15000 / (9000) | 360 | 120 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS500-90HP | 15000 / (9000) | 500 | 90 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS750-60HP | 15000 / (9000) | 750 | 60 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS1000-40HP | 15000 / (9000) | 1000 | 40 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS1500-30HP | 15000 / (9000) | 1500 | 30 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
DCS2000-20HP | 15000 / (9000) | 2000 | 20 | 208V ~ 480V - 3ø | 3U | 31 / 68.3 |
15kW Specifications
Model | DCS80-510HP | DCS200-210HP | DCS360-120HP | DCS500-90HP | DCS750-60HP | DCS1000-40HP | DCS1500-30HP | DCS2000-20HP |
---|---|---|---|---|---|---|---|---|
Voltage Range | 0~80 V | 0~200 V | 0~360 V | 0~500 V | 0~750 V | 0~1000 V | 0~1500 V | 0~2000 V |
Current Range | 0~510 A | 0~210 A | 0~120 A | 0~90 A | 0~60 A | 0~40 A | 0~30 A | 0~20 A |
CP V-I Range | 29.4V@510A ~ 80V@187.5A | 71.4V@210A ~ 200V@75A | 125V@120A ~ 360V@41.7A | 166.7V@90A ~ 500V@30A | 250V@60A ~ 750V@20A | 375V@40A ~ 1000V@15A | 500V@30A ~ 1500V@10 | 750V@20A ~ 2000V@7.5 |
Voltage Ripple | <100mVpp <10mVrms | <300mVpp <40mVrms | <320mVpp <55mVrms | <350mVpp <70mVrms | <800mVpp <200mVrms | <1600mVpp <300mVrms | <2400mVpp <400mVrms | <2400mVpp <400mVrms |
Current Ripple | <240 mArms | <66 mArms | <50 mArms | <48 mArms | <48 mArms | <22 mArms | <26 mArms | <26 mArms |
Insulation -DC to PE | ±600 Vdc | ±1000Vdc | ±1000Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc |
Insulation +DC to PE | ±600 Vdc | ±1000 Vdc | ±1000 Vdc | +2000 Vdc | +2000 Vdc | +2000 Vdc | +2000 Vdc | +2000 Vdc |
Power Range | 0~15000 W (9000 W) | 0~15000 W (9000 W) | 0~15000 W (9000 W)) | 0~15000 W (9000 W) | 0~15000 W (9000 W) | 0~15000 W (9000 W) | 0~15000 W (9000 W) | 0~15000 W (9000 W)) |
Efficiency | 94.5% | 94.5% | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% |
30kW Model Comparison
Model | Power (VA/W) | Max. Voltage (Vdc) | Max. Current (Adc) | Input Power | Height | Weight (Kg/Lbs) |
---|---|---|---|---|---|---|
DCS80-1000HP | 30000 / (18000) | 80 | 1000 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS200-420HP | 30000 / (18000) | 200 | 420 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS360-240HP | 30000 / (18000) | 360 | 240 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS500-180HP | 30000 / (18000) | 500 | 180 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS750-120HP | 30000 / (18000) | 750 | 120 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS1000-80HP | 30000 / (18000) | 1000 | 80 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS1500-60HP | 30000 / (18000) | 1500 | 60 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
DCS2000-40HP | 30000 / (18000) | 2000 | 40 | 208V ~ 480V - 3ø | 4U | 55 / 110 |
30kW Specifications
Model | DCS80-1000HP | DCS200-420HP | DCS360-240HP | DCS500-180HP | DCS750-120HP | DCS1000-80HP | DCS1500-60HP | DCS2000-40HP |
---|---|---|---|---|---|---|---|---|
Voltage Range | 0~80 V | 0~200 V | 0~360 V | 0~500 V | 0~750 V | 0~1000 V | 0~1500 V | 0~2000 V |
Current Range | 0~1000 A | 0~420 A | 0~240A | 0~180 A | 0~120 A | 0~80 A | 0~60 A | 0~40 A |
CP V-I Range | 30V@1000A ~ 80V@375A | 71.4V@420A ~ 200V@150A | 125V@240A ~ 360V@83.3A | 166.7V@180A ~ 500V@60A | 250V@120A ~ 750V@40A | 375V@80A ~ 1000V@30A | 500V@60A ~ 1500V@20A | 750V@40A ~ 2000V@15A |
Voltage Ripple | <480mVpp <37mVrms | <450mVpp <60mVrms | <480mVpp <83mVrms | <525mVpp <105mVrms | <1200mVpp <300mVrms | <2400mVpp <450mVrms | <3600mVpp <600mVrms | <3600mVpp <600mVrms |
Current Ripple | <480mArms | <120 mArms | <100 mArms | <96 mArms | <96 mArms | <45 mArms | <52 mArms | <52 mArms |
Insulation -DC to PE | ±500 Vdc | ±725 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc | ±1500 Vdc |
Insulation +DC to PE | ±600 Vdc | ±1000 Vdc | ±2000 Vdc | ±2000 Vdc | ±2000 Vdc | ±2000 Vdc | ±2000 Vdc | ±2000 Vdc |
Power Range | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W | 0~30000 W / 0-18000 W |
Efficiency | 94% | 94.2% | 94.6% | 95.3% | 95.5% | 94.6% | 95.3% | 95.5% |