CPS100

Single Phase AC & DC Power Source, up to 5kVA

CPS100

Single Phase AC & DC Power Source, up to 5kVA

Compact, versatile, and efficient, the CPS100 Series provides single-phase AC or DC power for development, testing, and production. With Series, Parallel, and 3-Phase modes, it scales easily for higher power and voltage needs.

Choose from 14 models (600VA/W to 5kVA) featuring advanced DSP technology for precision and efficiency. Perfect for aerospace or shipboard applications (50/60/400Hz or 360–800Hz) and AC, DC equipment testing.

Power: 600VA to 5kVA
Voltage: 0–150V / 0–300V; 0–212V / 0–424Vdc
Frequency: 15Hz–1000Hz

Why Choose CPS100 Series

Compact, Benchtop

2U-4U sizes with high efficiency

High Crest Factor & Low Voltage Distortion

Up to 6:1 for inrush current and real-world load testing

Transient Programming

Easy execution on front panel: LIST, STEP, and PULSE modes

Simple, Easy to Use

Advanced capabilities with simple set-up and execution

Key Specifications

  • Programmable AC, DC or AC+DC
  • 600VA to 5000VA per unit, scalable with series, parallel, or 3-phase modes.
  • 15–1000Hz, up to 1200Hz on E models
  • Dual Voltage Ranges: 0–150V / 0–300Vac (320V below 200Hz on larger models); 0–212V / 0–424Vdc
  • Constant power voltage range from 72% to F.S.
  • High Crest Factor up to 6:1 for inrush current testing
  • Low Voltage Distortion
  • Programmable Frequency and start/stop phase angle
  • Programmable Current and Power Limit Protection
  • Intuitive Color Touch Screen
  • Total of 15 Measurement functions in one screen
  • Transient Programming: LIST, STEP, and PULSE modes to simulate line distortion and dynamic conditions.
  • Sine Wave, Harmonic waveform library, User waveforms
  • Enhanced version (E) models add:
  • IEC 61000-4-11, 4-13, 4-14 and 4-28 Tests
  • Programmable L and R output impedance
  • Pass/Fail Test Mode
  • Harmonic & THD Measurements for V and I
  • TRIAC dimmer mode
  • Standard USB, RS232, RS485 with optional LAN/GPIB and Windows GUI software.
  • CE Mark

Advanced Testing of Low Power Applications

Easy to Use Front Panel

CPS100 models feature an intuitive interface with touch, keys, and rotary control, plus a large color LCD for waveform display and precise AC/DC measurements.

Easy Transient Programming on Front Panel

Program LIST, STEP, or PULSE transients directly from the front panel, with precise control over voltage, frequency, and AC phase angles. Save multiple lists to internal memory or USB and monitor active and total steps in real time—making complex line distortion simulations fast and intuitive.

High Current Crest Factor

The CPS100 AC & DC Power Source supports current crest factors up to 5 or 6 to 1. This allows proper evaluation of inrush current behavior for a wide range of real-world loads that don’t have adequate inrush limiter design or non power factor corrected AC inputs.

Model Comparison
ModelPower (VA/W)Output FormFrequency Range (HZ)Output Voltage Max (RMS)Output Amps (RMS)Output VDC Max.Output VDC Max.Input PowerHeightWeight (KG/LBS)
CPS106S600DC,15-1000150/3005.6/2.8212/4243.96/1.8990V ~ 265V2U15.9/35.0
CPS110S1000DC,15-1000150/3009.2/4.6212/4246.5/3.390V ~ 265V2U15.9/35.0
CPS115S1500DC,15-1000150/30013.8/6.9212/4249.76/4.88100V ~ 265V2U15.9/35.0
CPS120S2000DC,15-1000150/300

(or 320V < 200Hz)
16.0/8.0212/42411.3/5.65190V ~ 265V3U21.0/47.2
CPS130S3000DC,15-1000150/300

(or 320V < 200Hz)
27.6/13.8212/42419.6/9.8190V ~ 265V4U29.0/63.9
CPS140S4000DC,15-1000150/300

(or 320V < 200Hz)
32.0/16.0212/42422.6/11.3190V ~ 265V4U29.0/63.9
CPS150S5000DC,15-1000150/300

(or 320V < 200Hz)
46.0/23.0212/42432.6/16.3190V ~ 265V4U
Enhanced Model Comparison
ModelPower (VA/W)Output FormFrequency Range (HZ)Output Voltage Max (RMS)Output Amps (RMS)Output VDC Max.Output VDC Max.Input PowerHeightWeight (KG/LBS)
CPS106E600DC,15-1200150/3005.6/2.8212/4243.96/1.8990V ~ 265V2U15.9/35.0
CPS110E1000DC,15-1200150/3009.2/4.6212/4246.5/3.390V ~ 265V2U15.9/35.0
CPS115E1500DC,15-1200150/30013.8/6.9212/4249.76/4.88100V ~ 265V2U15.9/35.0
CPS120E2000DC,15-1200150/300

(or 320V < 200Hz)
16.0/8.0212/42411.3/5.65190V ~ 265V3U21.0/47.2
CPS130E3000DC,15-1200150/300

(or 320V < 200Hz)
27.6/13.8212/42419.6/9.8190V ~ 265V4U29.0/63.9
CPS140E4000DC,15-1200150/300

(or 320V < 200Hz)
32.0/16.0212/42422.6/11.3190V ~ 265V4U29.0/63.9
CPS150E5000DC,15-1200150/300

(or 320V < 200Hz)
46.0/23/0212/42432.6/16.3190V ~ 265V4U

Why Choose CPS100 Series

Compact, Benchtop

2U-4U sizes with high efficiency

High Crest Factor & Low Voltage Distortion

Up to 6:1 for inrush current and real-world load testing

Transient Programming

Easy execution on front panel: LIST, STEP, and PULSE modes

Simple, Easy to Use

Advanced capabilities with simple set-up and execution

Key Specifications

  • Programmable AC, DC or AC+DC
  • 600VA to 5000VA per unit, scalable with series, parallel, or 3-phase modes.
  • 15–1000Hz, up to 1200Hz on E models
  • Dual Voltage Ranges: 0–150V / 0–300Vac (320V below 200Hz on larger models); 0–212V / 0–424Vdc
  • Constant power voltage range from 72% to F.S.
  • High Crest Factor up to 6:1 for inrush current testing
  • Low Voltage Distortion
  • Programmable Frequency and start/stop phase angle
  • Programmable Current and Power Limit Protection
  • Intuitive Color Touch Screen
  • Total of 15 Measurement functions in one screen
  • Transient Programming: LIST, STEP, and PULSE modes to simulate line distortion and dynamic conditions.
  • Sine Wave, Harmonic waveform library, User waveforms
  • Enhanced version (E) models add:
  • IEC 61000-4-11, 4-13, 4-14 and 4-28 Tests
  • Programmable L and R output impedance
  • Pass/Fail Test Mode
  • Harmonic & THD Measurements for V and I
  • TRIAC dimmer mode
  • Standard USB, RS232, RS485 with optional LAN/GPIB and Windows GUI software.
  • CE Mark

Advanced Testing of Low Power Applications

Easy to Use Front Panel

CPS100 models feature an intuitive interface with touch, keys, and rotary control, plus a large color LCD for waveform display and precise AC/DC measurements.

Easy Transient Programming on Front Panel

Program LIST, STEP, or PULSE transients directly from the front panel, with precise control over voltage, frequency, and AC phase angles. Save multiple lists to internal memory or USB and monitor active and total steps in real time—making complex line distortion simulations fast and intuitive.

High Current Crest Factor

The CPS100 AC & DC Power Source supports current crest factors up to 5 or 6 to 1. This allows proper evaluation of inrush current behavior for a wide range of real-world loads that don’t have adequate inrush limiter design or non power factor corrected AC inputs.

Model Comparison
ModelPower (VA/W)Output FormFrequency Range (HZ)Output Voltage Max (RMS)Output Amps (RMS)Output VDC Max.Output VDC Max.Input PowerHeightWeight (KG/LBS)
CPS106S600DC,15-1000150/3005.6/2.8212/4243.96/1.8990V ~ 265V2U15.9/35.0
CPS110S1000DC,15-1000150/3009.2/4.6212/4246.5/3.390V ~ 265V2U15.9/35.0
CPS115S1500DC,15-1000150/30013.8/6.9212/4249.76/4.88100V ~ 265V2U15.9/35.0
CPS120S2000DC,15-1000150/300

(or 320V < 200Hz)
16.0/8.0212/42411.3/5.65190V ~ 265V3U21.0/47.2
CPS130S3000DC,15-1000150/300

(or 320V < 200Hz)
27.6/13.8212/42419.6/9.8190V ~ 265V4U29.0/63.9
CPS140S4000DC,15-1000150/300

(or 320V < 200Hz)
32.0/16.0212/42422.6/11.3190V ~ 265V4U29.0/63.9
CPS150S5000DC,15-1000150/300

(or 320V < 200Hz)
46.0/23.0212/42432.6/16.3190V ~ 265V4U
Enhanced Model Comparison
ModelPower (VA/W)Output FormFrequency Range (HZ)Output Voltage Max (RMS)Output Amps (RMS)Output VDC Max.Output VDC Max.Input PowerHeightWeight (KG/LBS)
CPS106E600DC,15-1200150/3005.6/2.8212/4243.96/1.8990V ~ 265V2U15.9/35.0
CPS110E1000DC,15-1200150/3009.2/4.6212/4246.5/3.390V ~ 265V2U15.9/35.0
CPS115E1500DC,15-1200150/30013.8/6.9212/4249.76/4.88100V ~ 265V2U15.9/35.0
CPS120E2000DC,15-1200150/300

(or 320V < 200Hz)
16.0/8.0212/42411.3/5.65190V ~ 265V3U21.0/47.2
CPS130E3000DC,15-1200150/300

(or 320V < 200Hz)
27.6/13.8212/42419.6/9.8190V ~ 265V4U29.0/63.9
CPS140E4000DC,15-1200150/300

(or 320V < 200Hz)
32.0/16.0212/42422.6/11.3190V ~ 265V4U29.0/63.9
CPS150E5000DC,15-1200150/300

(or 320V < 200Hz)
46.0/23/0212/42432.6/16.3190V ~ 265V4U