Battery Tester, up to 3.84MW
Battery Tester, up to 3.84MW
The EA-BT 20000 Series are advanced bidirectional battery testers designed for precise battery testing. Ideal for cells, packs, and modules, these systems provide full control of both charging and discharging with up to 30kW per unit and scalable operation to 1800A. With built-in regenerative technology, these battery testers recover over 96% energy back to the grid. Ideal for battery cycle life testing, R&D, and EV battery validation.
Why Choose EA-BT 20000
Ultimate flexibility for battery cell, module or pack tests with max. power of 3.84MW with high current
Accurate measurements with 1ms communication and fast, flexible connectivity to ensure fast, reliable data transfer
Triple the functions. Options for using one platform for battery test, battery emulation and battery recycling
Ideal for simultaneous testing of up to three battery packs with 4kW / 6kW or 10kW per channel
Key Specifications
- Designed for early, quick and accurate fault detection on high volume production lines
- Wide range input: 208V – 480V, +10%, 3ph AC
- Active power factor correction, typical 0.99
- Battery tester, 2-quadrant for charging and discharging
- In discharge mode regenerative with energy recovery back to the grid
- Regenerative Power over 96% energy efficiency
- Voltages from 0 – 10V up to 0 – 920V
- High power with up to 10kW per channel
- Currents from 0 – 40A up to 0 – 600A per channel
- Flexible power regulated DC output/input stages (autoranging)
- Control modes CV, CC, CP, CR with fast transition Digital control, high resolution with 16bit ADCs and DACs, control speed selection: Normal, Fast, Slow
- Galvanically isolated share bus for parallel operation
- Share-bus for parallel operation
- Built-in interfaces with 1ms communication speed
- Typical battery tester functionality integrated
- Integrated battery test mode, battery simulation
- Command languages and drivers: SCPI and ModBus, LabVIEW, IVI
Industry Leading Modular, Scalable Battery Cyclers
The EA‑BT 20000 Triple battery tester integrates three 10kW channels in a single 4U unit. Each channel can run independent battery tests for faster throughput or be combined to provide higher current for demanding test scenarios.
The EA‑BT 20000 Series battery tester delivers accurate voltage and current measurements with external sense, minimizing errors from voltage drops—especially at high currents. Triple-channel models and 1ms communication accelerate bench and automated testing, while active pre-charge, cable/connection checks, and overload protection reduce downtime and keep your battery testing running smoothly.
The EA‑BT 20000 Series battery tester features autoranging, delivering maximum power across a wide range of voltages and currents—even down to 33% of the rated output. Unlike traditional power supplies, which only reach full power at maximum voltage and current, autoranging ensures your battery tester maintains full output under real-world conditions. This allows a single tester to handle multiple voltage and current combinations, eliminating the need for multiple power supplies and streamlining battery testing workflows.
EA‑BT 20000 battery testers with regenerative technology recover up to 96% of the energy used during testing. Instead of wasting power as heat like traditional loads, recovered energy is fed back into the local grid—or even the public grid—reducing facility costs and improving test efficiency.
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 400 Triple 4U | 0–4 kW | 0–10 V | 0–400 A per channel | 3 Channels | |
| BT 20010 600 Triple 4U | 0–6 kW | 0–10 V | 0–600 A per channel | 3 Channels | |
| BT 20060 340 Triple 4U | 0–10 kW | 0–60 V | 0–340 A per channel | 3 Channels | |
| BT 20080 340 Triple 4U | 0–10 kW | 0–80 V | 0–340 A per channel | 3 Channels | |
| BT 20200 140 Triple 4U | 0–10 kW | 0–200 V | 0–140 A per channel | 3 Channels | |
| BT 20360 80 Triple 4U | 0–10 kW | 0–360 V | 0–80 A per channel | 3 Channels | |
| BT 20500 60 Triple 4U | 0–10 kW | 0–500 V | 0–60 A per channel | 3 Channels | |
| BT 20920 40 Triple 4U | 0–10 kW | 0–920 V | 0–40 A per channel | 3 Channels |
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 1000 4U | 0–10 kW | 0–10 V | 0–1000 A per channel | 1 Channel | |
| BT 20060 1000 4U | 0–30 kW | 0–60 V | 0–1000 A per channel | 1 Channel | |
| BT 20080 1000 4U | 0–30 kW | 0–80 V | 0–1000 A per channel | 1 Channel | |
| BT 20200 420 4U | 0–30 kW | 0–200 V | 0–420 A per channel | 1 Channel | |
| BT 20360 240 4U | 0–30 kW | 0–360 V | 0–240 A per channel | 1 Channel | |
| BT 20500 180 4U | 0–30 kW | 0–500 V | 0–180 A per channel | 1 Channel | |
| BT 20920 120 4U | 0–30 kW | 0–920 V | 0–120 A per channel | 1 Channel | |
| BT 21000 80 4U | 0–30 kW | 0–1000 V | 0–80 A per channel | 1 Channel | |
| BT 21500 60 4U | 0–30 kW | 0–1500 V | 0–60 A per channel | 1 Channel | |
| BT 22000 40 4U | 0–30 kW | 0–2000 V | 0–40 A per channel | 1 Channel |
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 600 3U | 0–6 kW | 0–10 V | 0–600 A per channel | 1 Channel | |
| BT 20060 500 3U | 0–15 kW | 0–60 V | 0–500 A per channel | 1 Channel | |
| BT 20080 500 3U | 0–15 kW | 0–80 V | 0–500 A per channel | 1 Channel | |
| BT 20200 210 3U | 0–15 kW | 0–200 V | 0–210 A per channel | 1 Channel | |
| BT 20360 120 3U | 0–15 kW | 0–360 V | 0–120 A per channel | 1 Channel | |
| BT 20500 90 3U | 0–15 kW | 0–500 V | 0–90 A per channel | 1 Channel | |
| BT 20920 60 3U | 0–15 kW | 0–920 V | 0–60 A per channel | 1 Channel | |
| BT 21000 40 3U | 0–15 kW | 0–1000 V | 0–40 A per channel | 1 Channel | |
| BT 21500 30 3U | 0–15 kW | 0–1500 V | 0–30 A per channel | 1 Channel | |
| BT 22000 20 3U | 0–15 kW | 0–2000 V | 0–20 A per channel | 1 Channel |
| Title | Document Type |
|---|---|
EA-BT 20000 4U 30kW Battery Tester
|
Datasheet |
EA-BT 20000 TRIPLE 4U 30 KW Three-channel Battery Tester
|
Datasheet |
Battery Test System Brochure
|
Brochure |
Why Choose EA-BT 20000
Ultimate flexibility for battery cell, module or pack tests with max. power of 3.84MW with high current
Accurate measurements with 1ms communication and fast, flexible connectivity to ensure fast, reliable data transfer
Triple the functions. Options for using one platform for battery test, battery emulation and battery recycling
Ideal for simultaneous testing of up to three battery packs with 4kW / 6kW or 10kW per channel
Key Specifications
- Designed for early, quick and accurate fault detection on high volume production lines
- Wide range input: 208V – 480V, +10%, 3ph AC
- Active power factor correction, typical 0.99
- Battery tester, 2-quadrant for charging and discharging
- In discharge mode regenerative with energy recovery back to the grid
- Regenerative Power over 96% energy efficiency
- Voltages from 0 – 10V up to 0 – 920V
- High power with up to 10kW per channel
- Currents from 0 – 40A up to 0 – 600A per channel
- Flexible power regulated DC output/input stages (autoranging)
- Control modes CV, CC, CP, CR with fast transition Digital control, high resolution with 16bit ADCs and DACs, control speed selection: Normal, Fast, Slow
- Galvanically isolated share bus for parallel operation
- Share-bus for parallel operation
- Built-in interfaces with 1ms communication speed
- Typical battery tester functionality integrated
- Integrated battery test mode, battery simulation
- Command languages and drivers: SCPI and ModBus, LabVIEW, IVI
Industry Leading Modular, Scalable Battery Cyclers
The EA‑BT 20000 Triple battery tester integrates three 10kW channels in a single 4U unit. Each channel can run independent battery tests for faster throughput or be combined to provide higher current for demanding test scenarios.
The EA‑BT 20000 Series battery tester delivers accurate voltage and current measurements with external sense, minimizing errors from voltage drops—especially at high currents. Triple-channel models and 1ms communication accelerate bench and automated testing, while active pre-charge, cable/connection checks, and overload protection reduce downtime and keep your battery testing running smoothly.
The EA‑BT 20000 Series battery tester features autoranging, delivering maximum power across a wide range of voltages and currents—even down to 33% of the rated output. Unlike traditional power supplies, which only reach full power at maximum voltage and current, autoranging ensures your battery tester maintains full output under real-world conditions. This allows a single tester to handle multiple voltage and current combinations, eliminating the need for multiple power supplies and streamlining battery testing workflows.
EA‑BT 20000 battery testers with regenerative technology recover up to 96% of the energy used during testing. Instead of wasting power as heat like traditional loads, recovered energy is fed back into the local grid—or even the public grid—reducing facility costs and improving test efficiency.
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 400 Triple 4U | 0–4 kW | 0–10 V | 0–400 A per channel | 3 Channels | |
| BT 20010 600 Triple 4U | 0–6 kW | 0–10 V | 0–600 A per channel | 3 Channels | |
| BT 20060 340 Triple 4U | 0–10 kW | 0–60 V | 0–340 A per channel | 3 Channels | |
| BT 20080 340 Triple 4U | 0–10 kW | 0–80 V | 0–340 A per channel | 3 Channels | |
| BT 20200 140 Triple 4U | 0–10 kW | 0–200 V | 0–140 A per channel | 3 Channels | |
| BT 20360 80 Triple 4U | 0–10 kW | 0–360 V | 0–80 A per channel | 3 Channels | |
| BT 20500 60 Triple 4U | 0–10 kW | 0–500 V | 0–60 A per channel | 3 Channels | |
| BT 20920 40 Triple 4U | 0–10 kW | 0–920 V | 0–40 A per channel | 3 Channels |
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 1000 4U | 0–10 kW | 0–10 V | 0–1000 A per channel | 1 Channel | |
| BT 20060 1000 4U | 0–30 kW | 0–60 V | 0–1000 A per channel | 1 Channel | |
| BT 20080 1000 4U | 0–30 kW | 0–80 V | 0–1000 A per channel | 1 Channel | |
| BT 20200 420 4U | 0–30 kW | 0–200 V | 0–420 A per channel | 1 Channel | |
| BT 20360 240 4U | 0–30 kW | 0–360 V | 0–240 A per channel | 1 Channel | |
| BT 20500 180 4U | 0–30 kW | 0–500 V | 0–180 A per channel | 1 Channel | |
| BT 20920 120 4U | 0–30 kW | 0–920 V | 0–120 A per channel | 1 Channel | |
| BT 21000 80 4U | 0–30 kW | 0–1000 V | 0–80 A per channel | 1 Channel | |
| BT 21500 60 4U | 0–30 kW | 0–1500 V | 0–60 A per channel | 1 Channel | |
| BT 22000 40 4U | 0–30 kW | 0–2000 V | 0–40 A per channel | 1 Channel |
| Model | Power | Voltage | Current Range | Channels | |
|---|---|---|---|---|---|
| BT 20010 600 3U | 0–6 kW | 0–10 V | 0–600 A per channel | 1 Channel | |
| BT 20060 500 3U | 0–15 kW | 0–60 V | 0–500 A per channel | 1 Channel | |
| BT 20080 500 3U | 0–15 kW | 0–80 V | 0–500 A per channel | 1 Channel | |
| BT 20200 210 3U | 0–15 kW | 0–200 V | 0–210 A per channel | 1 Channel | |
| BT 20360 120 3U | 0–15 kW | 0–360 V | 0–120 A per channel | 1 Channel | |
| BT 20500 90 3U | 0–15 kW | 0–500 V | 0–90 A per channel | 1 Channel | |
| BT 20920 60 3U | 0–15 kW | 0–920 V | 0–60 A per channel | 1 Channel | |
| BT 21000 40 3U | 0–15 kW | 0–1000 V | 0–40 A per channel | 1 Channel | |
| BT 21500 30 3U | 0–15 kW | 0–1500 V | 0–30 A per channel | 1 Channel | |
| BT 22000 20 3U | 0–15 kW | 0–2000 V | 0–20 A per channel | 1 Channel |
| Title | Document Type |
|---|---|
EA-BT 20000 4U 30kW Battery Tester
|
Datasheet |
EA-BT 20000 TRIPLE 4U 30 KW Three-channel Battery Tester
|
Datasheet |
Battery Test System Brochure
|