3D Series

Low Power AC & DC Load, up to 5.6kVA

3D Series

Low Power AC & DC Load, up to 5.6kVA

The Adaptive Power 3D Series Low Power AC & DC loads deliver versatile medium to high power testing, supporting up to 280Vac and 400Vdc. Each 19” 4U unit provides 1875W/VA, expandable to 3700VA with the -EPF option, and up to 5625VA in Master/Slave mode. The load handles sinusoidal, complex waveforms, simulates inductive or capacitive loads, and scales up to high-power, three-phase testing—ideal for inverters, UPS systems, transformers, and demanding R&D, production, and service applications.

Power: Up to 5625W; Parallel up to 5.6kVA
Voltage: 280Vac/400Vdc
Frequency: 40Hz-700Hz

Why Choose 3D Series

Dual AC/DC Capability

One versatile load for both AC and DC testing, supports up to 280Vac and 400Vdc

Compact Benchtop

Compact 19” 4U delivers 1875W/VA per unit, with options to scale higher

Built-In Test Modes

Simplify test with modes for UPS Efficiency, Transfer & Backup , PV Inverter, Battery, AC rectifier, Fuses, Inrush, and Surge Current

Unique Turbo-Mode

Doubles current and power for overload testing

Key Specifications

  • 1875W, 1875VA or 3750VA with -EPF option
  • Up to 5625VA/phase when paralleled
  • Master/Slave models at 7500VA/W and 11,250VA/W
  • Voltage Range: 50 – 2800Vac / 50 – 400Vdc
  • Frequency Range: 40Hz ~ 70Hz
  • Current Ranges 18.75Arms, 46.875Apk
  • Unique TURBO mode doubles current & power for overload testing
  • Programmable Current Crest Factor from 1.414 to 5.0
  • Leading and Lagging Power Factor (PF) 0.0 to ±1.0Inductive / Capacitive Load
  • High-Speed 5½ Digit Precision Metering Capability
  • Three-phase Delta & Wye Master mode
  • Voltage & Current Monitor Output Signals
  • Operating Modes: Constant Current (CC), Linear Constant Current (LCC), Constant Resistance (CR), Constant Voltage (CV), Crest Factor (CF) control, Rectifier mode, RLC Mode
  • Built-in Test Modes: UPS Efficiency, Transfer & Backup, PV Inverter, Battery, AC rectifier, Fuses, Inrush & Surge Current
  • Over Current, Over Power Protection Test Mode
  • Conventional and Linear CC Modes
  • LAN, USB, RS232 or GPIB Interfaces
  • CE Mark

Powerful, Flexible AC & DC Load Testing

Extensive Choice of AC & DC Load Operating Modes

The 3D Series AC & DC Loads provide a wide range of operating modes to accommodate diverse programmable load applications.

Constant Current Power Factor & Crest Factor Control

Programmable control of AC RMS Current, Crest Factor and Power Factor allows a wide range of real-world AC loads to be simulated to allow rigorous testing of your AC Power Supply or UPS designs.

Unique Turbo Mode

The 3D Series TURBO mode allows twice the maximum rated load current to be absorbed by the load for short periods of time. This mode is perfect for testing protection functions of power supplies such as over-current and over power protection. The same TURBO mode supports testing of current protection devices like Fuses and PTC’s without having to use an over-sided load. An example of an AC burst current without TURBO mode and one using TURBO mode is shown in the diagram.

Model Comparison
ModelDescriptionMax Power (W/VA)Max Voltage (V)Max Current (A)Rack Height
3D018-18AC&DC Electronic Load1875W / 1875VA280Vac / 400Vdc 1)18.754U
3D018-18-EPFAC&DC Electronic Load1875W / 3700VA280Vac / 500Vdc18.758U

Note 1): Extended PF Option -EPF increases apparent power range to from 1875VA to 3700VA. Specify -EPF option when ordering.

Why Choose 3D Series

Dual AC/DC Capability

One versatile load for both AC and DC testing, supports up to 280Vac and 400Vdc

Compact Benchtop

Compact 19” 4U delivers 1875W/VA per unit, with options to scale higher

Built-In Test Modes

Simplify test with modes for UPS Efficiency, Transfer & Backup , PV Inverter, Battery, AC rectifier, Fuses, Inrush, and Surge Current

Unique Turbo-Mode

Doubles current and power for overload testing

Key Specifications

  • 1875W, 1875VA or 3750VA with -EPF option
  • Up to 5625VA/phase when paralleled
  • Master/Slave models at 7500VA/W and 11,250VA/W
  • Voltage Range: 50 – 2800Vac / 50 – 400Vdc
  • Frequency Range: 40Hz ~ 70Hz
  • Current Ranges 18.75Arms, 46.875Apk
  • Unique TURBO mode doubles current & power for overload testing
  • Programmable Current Crest Factor from 1.414 to 5.0
  • Leading and Lagging Power Factor (PF) 0.0 to ±1.0Inductive / Capacitive Load
  • High-Speed 5½ Digit Precision Metering Capability
  • Three-phase Delta & Wye Master mode
  • Voltage & Current Monitor Output Signals
  • Operating Modes: Constant Current (CC), Linear Constant Current (LCC), Constant Resistance (CR), Constant Voltage (CV), Crest Factor (CF) control, Rectifier mode, RLC Mode
  • Built-in Test Modes: UPS Efficiency, Transfer & Backup, PV Inverter, Battery, AC rectifier, Fuses, Inrush & Surge Current
  • Over Current, Over Power Protection Test Mode
  • Conventional and Linear CC Modes
  • LAN, USB, RS232 or GPIB Interfaces
  • CE Mark

Powerful, Flexible AC & DC Load Testing

Extensive Choice of AC & DC Load Operating Modes

The 3D Series AC & DC Loads provide a wide range of operating modes to accommodate diverse programmable load applications.

Constant Current Power Factor & Crest Factor Control

Programmable control of AC RMS Current, Crest Factor and Power Factor allows a wide range of real-world AC loads to be simulated to allow rigorous testing of your AC Power Supply or UPS designs.

Unique Turbo Mode

The 3D Series TURBO mode allows twice the maximum rated load current to be absorbed by the load for short periods of time. This mode is perfect for testing protection functions of power supplies such as over-current and over power protection. The same TURBO mode supports testing of current protection devices like Fuses and PTC’s without having to use an over-sided load. An example of an AC burst current without TURBO mode and one using TURBO mode is shown in the diagram.

Model Comparison
ModelDescriptionMax Power (W/VA)Max Voltage (V)Max Current (A)Rack Height
3D018-18AC&DC Electronic Load1875W / 1875VA280Vac / 400Vdc 1)18.754U
3D018-18-EPFAC&DC Electronic Load1875W / 3700VA280Vac / 500Vdc18.758U

Note 1): Extended PF Option -EPF increases apparent power range to from 1875VA to 3700VA. Specify -EPF option when ordering.