SmartTS-PV Series

Inverter Grid Compliance Test System – IEEE 1547.1 / UL1741.SB

SmartTS-PV Series

Inverter Grid Compliance Test System – IEEE 1547.1 / UL1741.SB

The SmartTS-PV Inverter Test System is a complete automated platform for testing PV inverters, energy storage systems (ESS), and distributed energy resources (DERs) to IEEE 1547.1, UL 1741 SB and European EN50549 grid interconnection standards.

The SmartTS-PV is is the first of it’s kind integrated 1547.1 test system. Designed for inverter manufacturers, certification labs, utilities, and R&D teams, the SmartTS-PV integrates grid simulation, DC power, precision measurement, and compliance automation into a single platform.

Power: 15kW, 30kW, 55kW, 60kW
Voltage: System Dependent
Frequency: up to 200Hz

Why Choose SmartTS-PV Series

All-in-1

Fully integrated test system reduces barriers for testing to IEEE 1547.1, UL1741, EN50495. Get started out of the box.

Compact & Streamlined

Eliminate complexity of multiple units and control systems.

Accelerate Testing Time

Complete testing in 32 hours vs. 8-12 NRTL estimate of manual test time using QualityLogic integrated software.

Easy to Use Platform

We simplify test. Get ONE integrated platform and ONE point of contact for support.

Key Specifications

  • Turnkey IEEE 1547.1 / UL 1741 SB / EN50549 test system
  • Integrated AC grid simulator + DC source + measurement
  • Automated compliance test software by QualityLogic
  • Instant pass/fail reporting
  • Pre-wired cabinet for fast deployment
  • Optimized for Pre-Compliance & Certification
  • Advanced grid disturbance simulation
  • Complete IEEE 1547.1 compliance test system
  • Automated UL 1741 SB certification testing
  • Integrated grid simulator + DC source + measurement
  • Reduced lab setup time single vendor support
  • Pre-wired cabinet for fast deployment

The Industry's First of its Kind All-In-1 IEEE 1547.1 Grid Compliance Testing

De-Risk IEEE 1547.1 Grid Compliance Testing. Accelerate Certification. Validate with Confidence.

As grid interconnection standards continue to evolve, PV inverter manufacturers face increasing pressure to validate complex grid-support behaviors under tightly controlled conditions. Requirements such as IEEE 1547, UL 1741 SB, and EN 50549 demand advanced functionality—voltage ride-through, frequency response, anti-islanding, and reactive power control—tested across a wide range of dynamic grid scenarios.

Traditional test setups—fragmented across multiple instruments and vendors—introduce integration challenges, limit repeatability, and extend certification timelines.

SmartTS is a fully integrated, turnkey inverter test system designed to eliminate these constraints—enabling faster validation, reduced risk, and complete certification readiness.

SmartTS-PV Inverter Test System Takes You From Compliance Burden to Competitive Advantage

SmartTS-PV transforms inverter testing from a bottleneck into a strategic capability. Validate against certification requirements early in the development cycle—reducing downstream risk and rework.

  • Accelerate Time-to-Certification: Pre-validate against global standards before entering third-party labs. Reduce test iterations, avoid scheduling delays, and move through certification with
    confidence.
  • De-Risk Product Development: Simulate abnormal grid conditions safely and repeatably. Identify edge-case failures early—before they become costly redesigns or certification failures.
  • Lower Total Cost of Test: Replace complex, multi-vendor setups with a single integrated platform. Reduce reliance on external labs and minimize engineering overhead.
  • Future-Proof Your Test Capability: Adapt to evolving grid codes and next-generation inverter requirements without re-architecting your lab infrastructure.
High Performance Grid Compliance Testing Capabilities

The SmartTS PV Inverter Test System enables comprehensive validation of critical DER grid support functions required for UL 1741 SB and IEEE 1547.1 compliance. These functional tests—such as ride-through, frequency-watt, and volt-var—are executed and automated using QualityLogic’s 1547.1 test software, which manages test sequencing, timing, and data capture. Pacific Power Source grid simulators provide the precise voltage and frequency disturbances, along with source and load capabilities, needed to replicate real-world grid conditions.

Together, the software and grid simulator create a coordinated test environment that ensures accurate, repeatable validation of inverter performance against utility interconnection requirements.

Anti-Islanding Test Mode – Option P for PV & DER ValidationAnti-Islanding Test Mode – Option P for PV & DER Validation

Anti-islanding verification is a required step for certifying Distributed Energy Resources (DER), including PV inverters and bidirectional V2G EV chargers, to meet grid interconnection standards. Pacific Power Source’s Option P provides a dedicated anti-islanding test mode integrated into AZX and GSZ grid simulators.

With Option P activated, the system digitally replicates the resonant RLC load profile needed for testing, initiates the simulated grid loss condition, and captures inverter trip response time using a built-in digital oscilloscope.

This integrated approach enables the grid simulator to serve as a complete anti-islanding test solution—combining grid simulation, load emulation, and precise timing measurement in a single platform—eliminating the need for additional hardware, instrumentation, or custom-developed test scripts.

Simplify Testing Using Automated IEEE 1547.1, UL1741SB, and EN50549 Software Tools from QualityLogic

The SmartTS PV Inverter Test System combines fully integrated hardware with advanced automation software to deliver a true turnkey solution for UL 1741 SB and IEEE 1547.1 testing. Powered by QualityLogic’s 1547.1 test tools, the system uses a standard SCPI interface to automatically configure, control, and capture data from all supported equipment for each of the IEEE 1547.1 grid support tests—eliminating the need for custom scripting.

QualityLogic’s test software includes use of required interoperability protocols and automatic data analysis that evaluates your device’s power responses to the IEEE 1547 functions to assess its compliance to the performance requirements.

By standardizing and automating complex test sequences, SmartTS significantly reduces setup time, improves test consistency, and can accelerate certification timelines from months to weeks, helping manufacturers bring products to market faster.

Testing can now be completed in approximately 32 hours of actual test time versus IREC’s 8-12 week estimate for manual NRTL testing, significantly accelerating certification timelines.

  • Controls multiple units
  • Automates measurements
  • Speeds up testing
  • No need for in-depth standards knowledge
  • Training and technical support available
Featured Press Release

New SmartTS-PV Inverter Test System for Grid Compliance Press Release

Learn how this first-of-its-kind all in one platform will transform how inverters, DER, and V2G systems are tested for compliance.

SmartTS-PV Inverter AC Power Source Selection
SmartTS-PV SystemAC Power SourceAC Voltage RangeAC Max Current (Arms/Ø) @ 120Vl-n (RMS)AC Max current (Arms/Ø) @ 277Vl-n (RMS)
SmartTS-PV-15kW3150RGS0-350Vl-n42 Arms, 3 Phs mode18 Arms, 3 Phs mode
SmartTS-PV-30kW3300RGS or GSZ0-350Vl-n (RGS) / 0-480Vl-n (GSZ)84 Arms / 83.3 Arms36 Arms / 36.1 Arms
SmartTS-PV-60kW3630RGS or 3550GSZ0-350Vl-n (RGS) / 0-480Vl-n (GSZ)126 Arms / 130 Arms75.8 Arms / 66 Arms
SmartTS-PV-CustomAdditional variants are available dependent on application requirements.
PPS Products include: RGS, GSZ Series
SmartTS-PV Inverter DCPower Supply
SmartTS-PV SystemDC Power RatingDC Voltage RangeMax. DC Current
SmartTS-PV-15kW15kW60V to 2000Vdc (model dependent)510Adc
SmartTS-PV-30kW30kW60V to 2000Vdc (model dependent)1000Adc
SmartTS-PV-60kW60kW60V to 2000Vdc (model dependent)2000Adc
SmartTS-PV-CustomAdditional variants are available dependent on application requirements.
Standard systems include an unidirection DC power supply at the customer's required voltage range. Regenerative versions are available.

Why Choose SmartTS-PV Series

All-in-1

Fully integrated test system reduces barriers for testing to IEEE 1547.1, UL1741, EN50495. Get started out of the box.

Compact & Streamlined

Eliminate complexity of multiple units and control systems.

Accelerate Testing Time

Complete testing in 32 hours vs. 8-12 NRTL estimate of manual test time using QualityLogic integrated software.

Easy to Use Platform

We simplify test. Get ONE integrated platform and ONE point of contact for support.

Key Specifications

  • Turnkey IEEE 1547.1 / UL 1741 SB / EN50549 test system
  • Integrated AC grid simulator + DC source + measurement
  • Automated compliance test software by QualityLogic
  • Instant pass/fail reporting
  • Pre-wired cabinet for fast deployment
  • Optimized for Pre-Compliance & Certification
  • Advanced grid disturbance simulation
  • Complete IEEE 1547.1 compliance test system
  • Automated UL 1741 SB certification testing
  • Integrated grid simulator + DC source + measurement
  • Reduced lab setup time single vendor support
  • Pre-wired cabinet for fast deployment

The Industry's First of its Kind All-In-1 IEEE 1547.1 Grid Compliance Testing

De-Risk IEEE 1547.1 Grid Compliance Testing. Accelerate Certification. Validate with Confidence.

As grid interconnection standards continue to evolve, PV inverter manufacturers face increasing pressure to validate complex grid-support behaviors under tightly controlled conditions. Requirements such as IEEE 1547, UL 1741 SB, and EN 50549 demand advanced functionality—voltage ride-through, frequency response, anti-islanding, and reactive power control—tested across a wide range of dynamic grid scenarios.

Traditional test setups—fragmented across multiple instruments and vendors—introduce integration challenges, limit repeatability, and extend certification timelines.

SmartTS is a fully integrated, turnkey inverter test system designed to eliminate these constraints—enabling faster validation, reduced risk, and complete certification readiness.

SmartTS-PV Inverter Test System Takes You From Compliance Burden to Competitive Advantage

SmartTS-PV transforms inverter testing from a bottleneck into a strategic capability. Validate against certification requirements early in the development cycle—reducing downstream risk and rework.

  • Accelerate Time-to-Certification: Pre-validate against global standards before entering third-party labs. Reduce test iterations, avoid scheduling delays, and move through certification with
    confidence.
  • De-Risk Product Development: Simulate abnormal grid conditions safely and repeatably. Identify edge-case failures early—before they become costly redesigns or certification failures.
  • Lower Total Cost of Test: Replace complex, multi-vendor setups with a single integrated platform. Reduce reliance on external labs and minimize engineering overhead.
  • Future-Proof Your Test Capability: Adapt to evolving grid codes and next-generation inverter requirements without re-architecting your lab infrastructure.
High Performance Grid Compliance Testing Capabilities

The SmartTS PV Inverter Test System enables comprehensive validation of critical DER grid support functions required for UL 1741 SB and IEEE 1547.1 compliance. These functional tests—such as ride-through, frequency-watt, and volt-var—are executed and automated using QualityLogic’s 1547.1 test software, which manages test sequencing, timing, and data capture. Pacific Power Source grid simulators provide the precise voltage and frequency disturbances, along with source and load capabilities, needed to replicate real-world grid conditions.

Together, the software and grid simulator create a coordinated test environment that ensures accurate, repeatable validation of inverter performance against utility interconnection requirements.

Anti-Islanding Test Mode – Option P for PV & DER ValidationAnti-Islanding Test Mode – Option P for PV & DER Validation

Anti-islanding verification is a required step for certifying Distributed Energy Resources (DER), including PV inverters and bidirectional V2G EV chargers, to meet grid interconnection standards. Pacific Power Source’s Option P provides a dedicated anti-islanding test mode integrated into AZX and GSZ grid simulators.

With Option P activated, the system digitally replicates the resonant RLC load profile needed for testing, initiates the simulated grid loss condition, and captures inverter trip response time using a built-in digital oscilloscope.

This integrated approach enables the grid simulator to serve as a complete anti-islanding test solution—combining grid simulation, load emulation, and precise timing measurement in a single platform—eliminating the need for additional hardware, instrumentation, or custom-developed test scripts.

Simplify Testing Using Automated IEEE 1547.1, UL1741SB, and EN50549 Software Tools from QualityLogic

The SmartTS PV Inverter Test System combines fully integrated hardware with advanced automation software to deliver a true turnkey solution for UL 1741 SB and IEEE 1547.1 testing. Powered by QualityLogic’s 1547.1 test tools, the system uses a standard SCPI interface to automatically configure, control, and capture data from all supported equipment for each of the IEEE 1547.1 grid support tests—eliminating the need for custom scripting.

QualityLogic’s test software includes use of required interoperability protocols and automatic data analysis that evaluates your device’s power responses to the IEEE 1547 functions to assess its compliance to the performance requirements.

By standardizing and automating complex test sequences, SmartTS significantly reduces setup time, improves test consistency, and can accelerate certification timelines from months to weeks, helping manufacturers bring products to market faster.

Testing can now be completed in approximately 32 hours of actual test time versus IREC’s 8-12 week estimate for manual NRTL testing, significantly accelerating certification timelines.

  • Controls multiple units
  • Automates measurements
  • Speeds up testing
  • No need for in-depth standards knowledge
  • Training and technical support available
Featured Press Release

New SmartTS-PV Inverter Test System for Grid Compliance Press Release

Learn how this first-of-its-kind all in one platform will transform how inverters, DER, and V2G systems are tested for compliance.

SmartTS-PV Inverter AC Power Source Selection
SmartTS-PV SystemAC Power SourceAC Voltage RangeAC Max Current (Arms/Ø) @ 120Vl-n (RMS)AC Max current (Arms/Ø) @ 277Vl-n (RMS)
SmartTS-PV-15kW3150RGS0-350Vl-n42 Arms, 3 Phs mode18 Arms, 3 Phs mode
SmartTS-PV-30kW3300RGS or GSZ0-350Vl-n (RGS) / 0-480Vl-n (GSZ)84 Arms / 83.3 Arms36 Arms / 36.1 Arms
SmartTS-PV-60kW3630RGS or 3550GSZ0-350Vl-n (RGS) / 0-480Vl-n (GSZ)126 Arms / 130 Arms75.8 Arms / 66 Arms
SmartTS-PV-CustomAdditional variants are available dependent on application requirements.
PPS Products include: RGS, GSZ Series
SmartTS-PV Inverter DCPower Supply
SmartTS-PV SystemDC Power RatingDC Voltage RangeMax. DC Current
SmartTS-PV-15kW15kW60V to 2000Vdc (model dependent)510Adc
SmartTS-PV-30kW30kW60V to 2000Vdc (model dependent)1000Adc
SmartTS-PV-60kW60kW60V to 2000Vdc (model dependent)2000Adc
SmartTS-PV-CustomAdditional variants are available dependent on application requirements.
Standard systems include an unidirection DC power supply at the customer's required voltage range. Regenerative versions are available.