NHR 9430 Series Regenerative Load Product Replacement
Replace EOL NHR 9430 Systems with Pacific Power Source
The NH Research / NI NHR 9430 is approaching end of life support by 12/31/2026. Transition to find a new Regenerative 4 Quadrant Load with next generation capabilities, higher power density, and better built-in software capabilities for easy user control. Not only is our product an ideal replacement, but our team has direct expertise of NHR products and can help you easily transition. Contact our sales team today at sales@ppstsolutions.com.
NHR 9430 vs. PPS RLS Series Comparison
NHR 9430
- Larger in size and weight / 9U
- Power Range Max at 96kW
- Lower current availability
- CC, CP, CR Modes only
- 10 year+ old technology
- Limited Support
Pacific Power RLS Series
- Higher Power Density up to 21kVA / 4U
- Higher Power Range to 756 kVA/kW
- Higher DC Voltage Range: 0 – ±500 VDC
- ~40% Higher Current
- CC, CP, CR, CP+CR, CS Rectifier Modes
- Better Built-in Smart S/W Solution
- Firmware updates for latest enhancements
- Excellent, accessible support teams with NHR Experience
Why Choose Pacific Power Source to Replace NHR 9430?
Aside from our high-performance solutions, our in-house engineering development and application teams have extensive, hands-on knowledge of NHR products. You might even recognize some similar faces. Save time and headaches. We have the know-how and solutions to help you transition seamlessly. Contact us, today.
Advanced Tech
We invest in R&D and Innovation. to add customer value using the latest technology and approaches.
Future Proofing
Our solutions are safe, reliable, and flexible. designed to evolve with technology.
Expertise
Unlike other vendors, our engineering and application teams are well-versed in NHR products. Help is within easy reach.
Comparison of Banner Specs
*Based on highest power configuration in single unit.
| Key Features | NHR 9430 | Pacific Power RLS Series |
|---|---|---|
| Power Density | up to 12kW / 9U | ~4x Higher Power Density up to 21kW / 4U |
| Voltage | 10-175VLN / 17-303VLL and 10-350VLN / 17-606VLL; 0 – ±500 VDC | 30 – 350 VLN / 50 – 606 VLL; DC Range: 0 – ±500 VDC |
| Current | 3Φ Mode: 30 Arms; 1Φ Mode: 90 Arms | 40% More Current 3Φ Mode: 42 Arms; 1Φ Mode: 126 Arms |
| Power | Parallel max up to 96kW | Parallel max up to 252kW. Three-Phase Systems to 756kW |
| Frequency | 30-100 Hz (Option 880Hz) | Higher Frequency 15-1200Hz |
| PF | PF -1 to 1 | PF -1 to 1 |
| Load Modes | CC, CP, CR | CC, CP, CR, CP+CR, CS Rectifier |
| Output Forms | Multi-Channel Configuration 6 (3 Phs, 1 Phs, 3x 1 Phs, 1 Phs, Split-Phs + 1 Phs, 2 x 1Phs + 1 Ph) | Multi-Channel Configuration 6 (1 Phs, Split-Phs, 3 Phs, 2 x 1 Phs, 3 x 1 Ph, Split-Phs + 1 Phs) |
| Digital/Analog I/O | LAN (SCPI Syntax) | Several Interfaces: LAN, GPIB, RS232 & USB Interfaces, CAN FD/ModBus, Analog Control |
| Software | Enerchron | Better Software Capabilities Built-In SmartSource Suite |
| Regulatory | None | CE / NRTL Nemko US/Canada |
Test Smarter with Pacific Power Source. Make the Switch.
Highest Current on the Market
Provides more current from 120V to 200V (42A) compared to competitor (35A) per phase. 20% more current over competitors at lower voltage.
40% more current over NHR based on the highest power configuration in single building block. (12kW for NHR vs 21kW for PPS).
Replace NHR 9430 AC Loads with High Power Density of 75% Increase in True Power per Unit. Modular, Scalable Power up to 1.296MW Systems.
*Note: Green Boxes indicate the number of modules required to reach approximately the same power level.
NHR Limited power up to 96 kW. This large cabinet is equivalent to only 5 x 4U RLS Series with Pacific Power Source.
Parallel up to 189kW per cabinet, or up to 256 kW for two cabinets. Three-Phase systems up to 756kW.
Several Load Modes
The RLS Series offers a several load modes.
Note: ELZ Series has additional Circuit Emulation Mode.
Flexible Multi-Channel Configurations
The RLS Series can operate in each phase as a different function: voltage source, current source, or load (option), providing the most similar configuration to NHR than other vendors on the market.
Test Smarter with Built-In Smart Source Suite Software
Easily control and operate our power units with intuitive, user-friendly multiple control options and additional interfaces over NHR.
- Touch-Screen Visual Panel
- Intuitive Menu and Soft-keys
- Shuttle Knob, Numeric Entry Pad
- LAN, GPIB, RS232 & USB Interfaces, CAN FD/ModBus, Analog Control
- Built-In SmartSource Suite – Embedded Web Server for Both LAN and USB Interface
Easily Simulate Any Load
Simulate any AC or DC linear, non-linear loads with several emulation modes and the highest degree of flexibility. Right-sized power; scale power later as needed.
Contact us to help you transition, now.
FAQ
Is the NH Research (NHR) 9430 regenerative AC load being discontinued?
Yes. The NHR 9430 series is part of NH Research’s legacy product line, which NI (National Instruments) — now owned by Emerson — has been winding down following its acquisition of NH Research. Distributor notices cite a planned discontinuation around October 2025, with spare parts and support continuing only through the end of 2026. After that window, sourcing parts, calibration, and repair for a 9430 gets harder and more expensive every year.
What does Pacific Power Source offer as a replacement for the NHR 9430?
Pacific Power Source’s RLS series (compact regenerative AC & DC load) is the direct like-for-like replacement for most 9430 configurations, and the ELZ series (high-power regenerative AC & DC load) is the upgrade path for customers who need more power headroom or grid-fault/PHIL emulation on top of standard load testing. Both are regenerative, 4-quadrant designs built for the same class of application — UPS, inverter, AC source, switchgear, and component testing — that the 9430 was used for.
Which replaces the 9430 more closely — RLS or ELZ?
For most installed 9430 units (the 9430-4 through 9430-96, spanning roughly 4–96 kW), RLS is the closer match: it covers 6–24 kVA per unit and scales to 1.296 MVA+, overlapping the 9430’s full power range. ELZ starts at 30 kVA and scales to 1.1 MVA+, and adds optional PHIL (power-hardware-in-the-loop) support — the right choice if you’re consolidating several 9430 cabinets into fewer higher-power units, or need grid-simulation capability the 9430 never had. Talk to a Pacific Power Source applications engineer with your current 9430 model/power rating to confirm the exact match.
Does the RLS or ELZ series test both AC and DC loads, like the 9430 does?
The RLS and ELZ go further: the 9430 is an AC-only load, while RLS and ELZ both test AC and DC loads from the same chassis — useful if your test plan has grown to include DC-bus or battery-adjacent work since the 9430 was first specified.
Will switching from a 9430 to RLS or ELZ mean rebuilding my test scripts or automation?
It depends on your current control setup — bring your existing test-sequence and remote-control (SCPI/automation) requirements to a Pacific Power Source applications engineer, and they’ll map out what carries over directly and what needs re-pointing.
Can I replace multiple 9430 units with fewer RLS or ELZ cabinets?
Often, yes. Both series scale well beyond single-9430 power levels (RLS to 1.296 MVA+, ELZ to 1.1 MVA+), so a lab running several 9430 cabinets in parallel for higher aggregate power can frequently consolidate into fewer, higher-power RLS or ELZ units — simplifying floor space, wiring, and maintenance. Exact consolidation math depends on your present configuration.
Who should I talk to about replacing a 9430 before it fails?
Contact a Pacific Power Source applications engineer with your current 9430 model number(s) and power rating(s). They’ll confirm whether RLS or ELZ is the right match, what (if anything) changes in your test setup, and lead times — before you’re forced into an unplanned replacement.
Expert Help You Can Trust
Don’t know where to start? That’s what our technical customer service