NHR 9410 and 9420 Series Grid Simulator Product Replacement

NHR 9410 and 9420 Series Grid Simulator Product Replacement

Replace EOL NHR 9410 and 9420 Systems with Pacific Power Source

The NH Research / NI NHR 9430 is approaching end of life support by 12/31/2026. Transition to find a new Regenerative 4 Quadrant Load with next generation capabilities, higher power density, and better built-in software capabilities for easy user control. Not only is our product an ideal replacement, but our team has direct expertise of NHR products and can help you easily transition. Contact our sales team today at sales@ppstsolutions.com.

NHR 9410/9420 vs. PPS RGS Series Comparison

NH Research NHR 9410/9420 regenerative grid simulator

NHR 9410/9420

  • Larger in size and weight / 9U
  • Power Range Max at 96kW
  • Lower Voltage Range
  • Voltage starts at 10V to 17V, not 0
  • Lower current availability
  • 10 year+ old technology
  • No Load Option
  • Limited Support
Pacific Power RGS Series grid simulator, a compact replacement for NHR 9410/9420: 57% Smaller in Rack Space, 75% More True Power, ~4X Power Density, ~300% More Power per kW

Pacific Power RGS Series

  • Higher Power Density up to 24kVA / 4U
  • Higher Power Range to 1.296MW
  • Higher DC Voltage up to 500V
  • Zero Voltage Starting Range
  • 2-in-1 Load Option
  • ~40% Higher Current
  • 2s Overload Capability
  • Better Built-in Smart S/W Solution
  • Firmware updates for latest enhancements
  • Excellent, accessible support teams with NHR Experience

Why Choose Pacific Power Source?

Aside from our high-performance solutions, our in-house engineering development and application teams have extensive, hands-on knowledge of NHR products. You might even recognize some similar faces. Save time and headaches. We have the know-how and solutions to help you transition seamlessly. Contact us, today.

Advanced Tech

We invest in R&D and Innovation. to add customer value using the latest technology and approaches.

Future Proofing

Our solutions are safe, reliable, and flexible. designed to evolve with technology.

Expertise

Unlike other vendors, our engineering and application teams are well-versed in NHR products. Help is within easy reach.

Comparison of Banner Specs

*Based on highest power configuration in single unit.

Key FeaturesNHR 9410/9420Pacific Power RGS Series
Power Densityup to 12kW / 9U~4x Higher Power Density
up to 21kW / 4U
Voltage10-175VLN / 17-303VLL;
10-350VLN / 17-606VLL
Zero Starting Voltage
0-350VLN / 0-606VLL
(0-365VLN / 0-632VLL Option)
Higher DC Voltage up to 500V
Current3Φ Mode: 30 Arms;
1Φ Mode: 90 Arms
40% More Current
3Φ Mode: 42 Arms;
1Φ Mode: 126 Arms
PowerParallel max up to 96kWParallel max up to 252kW.
Three-Phase Systems to 756kW
Frequency30-100 Hz (Option 880Hz)Higher Frequency
15-200Hz (Option 15 to 1200Hz)
THD<1% at 50/60Hz3X Lower Distortion
<0.3% at < 100Hz
Output FormsMulti-Channel Configuration
6 (3 Phs, 1 Phs, 3x 1 Phs, 1 Phs, Split-Phs + 1 Phs, 2 x 1Phs + 1 Ph)
Multi-Channel Configuration
6 (1 Phs, Split-Phs, 3 Phs, 2 x 1 Phs, 3 x 1 Ph, Split-Phs + 1 Phs)
Digital/Analog I/OLAN (SCPI Syntax)Several Interfaces: LAN, GPIB, RS232 & USB Interfaces, CAN FD/ModBus, Analog Control
SoftwareEnerchronBetter Software Capabilities
Built-In SmartSource Suite and Pre-Written Test Sequences.
RegulatoryNoneCE / NRTL Nemko US/Canada

Test Smarter with Pacific Power Source. Make the Switch.

Highest Current on the Market

Provides more current from 120V to 200V (42A) compared to competitor (35A) per phase. 20% more current over competitors at lower voltage.

40% more current over NHR based on the highest power configuration in single building block. (12kW for NHR vs 21kW for PPS).

Available RMS current vs AC voltage: RGS Series 42 A vs competitor 35 A vs NHR
SmartSource Suite current and power factor plots showing the RGS Series 2 s overload

2s Overload Capability

Supplies 130% of rated current for 2s. No need to oversize equipment for short duration overload conditions

High Power Density with 75% Increase in True Power per Unit. Modular, Scalable Power up to 756kW Systems.

*Note: Green Boxes indicate the number of modules required to reach approximately the same power level.

NHR 9410 96 kW cabinet system

NHR Limited power up to 96kW. This large cabinet is equivalent to only 5 x 4U RGS Series with Pacific Power Source.

RGS Series 4U modules in parallel cabinets up to 756 kW

Parallel up to 189kW per cabinet, or up to 256kW for two cabinets. Three-Phase systems up to 756kW.

2-in-1 Grid Sim AND Load Option

The RGS Series offers a Load Option which eliminates the need for another instrument.

RGS Series load option AC and DC load modes

Flexible Multi-Channel Configurations

The RGS Series can operate in each phase as a different function: voltage source, current source, or load (option), providing the most similar configuration to NHR than other vendors on the market. The addition of the load mode offers even more flexibility.

NHR 9410 multi-channel configuration
NHR 9410 Configuration
PPS RGS Series multi-channel configuration forms 1 to 6
PPS RGS Configuration

Test Smarter with Built-In Smart Source Suite Software

Easily control and operate our power units with intuitive, user-friendly multiple control options and additional interfaces over NHR

  • Touch-Screen Visual Panel
  • Intuitive Menu and Soft-keys
  • Shuttle Knob, Numeric Entry Pad
  • LAN, GPIB, RS232 & USB Interfaces, CAN FD/ModBus, Analog Control
  • Built-In SmartSource Suite – Embedded Web Server for Both LAN and USB Interface
  • Pre-Written Test Sequence Standards
SmartSource Suite software on laptop, desktop, tablet and phone browsers
SmartSource Suite on any web browser for enhanced visualization, built-in.

Contact us to help you transition, now.

FAQ

 Are the NH Research (NHR) 9410 and 9420 being discontinued? 

Yes. Both are part of NH Research’s legacy lineup now owned by NI (National Instruments) — itself acquired by Emerson in 2023 — which has been sunsetting older NHR product lines.

 What does Pacific Power Source offer as a replacement for the 9410/9420? 

The RGS series Grid Simulator  is the direct replacement for most 9410/9420 configurations — a 2-in-1 regenerative grid simulator with an optional AC/DC load, built for IEEE 1547, UL 1741, and comparable grid-tied compliance testing. The GSZ series is the upgrade path: it adds a Power-Hardware-in-the-Loop (PHIL) interface on top of the same grid-simulator feature set, for customers who need real-time grid-fault emulation beyond what the 9410 offered.

How much more power density does RGS deliver than the 9410/9420?

Per Pacific Power Source’s published comparison: RGS delivers roughly 4x the power density of the NHR 9410/9420 — up to 24 kW in a single 4U chassis versus the NHR’s 12 kW in 9U — plus 57% smaller rack space for an equivalent build-out.

Does RGS provide more usable power than the 9410/9420 at the same rating?

Yes, per the same published comparison: RGS delivers 75% more true power and roughly 40% more current at the building-block level (42A vs. 30A single-phase; 126A vs. 90A three-phase), adding up to ~300% more power per kW claimed overall. Total system scaling is also higher — up to 432 kW parallel / 1.296 MW in three-phase configurations, versus the NHR’s 96 kW parallel ceiling.

Does RGS/GSZ cover the same voltage and frequency range as the 9410/9420?

It meets or exceeds it. The NHR 9410/9420 start at a 10V floor (10–175V / 10–350V ranges) and run 30–100 Hz; RGS and GSZ start from true zero-volt (0–350 Vac L-N / 0–606 Vac L-L, with a 500V DC option) and cover 15–200 Hz, with an optional 15–1,200 Hz range — a wider window on both the low-voltage and high-frequency ends.

Which one replaces my 9410/9420 — RGS or GSZ?

If you’re doing straightforward grid-simulator or AC-source testing — IEEE 1547, UL 1741, general compliance — RGS is the closer, direct match. If your test plan needs real-time grid-fault or disturbance emulation via PHIL (power-hardware-in-the-loop), GSZ adds that capability on the same platform. Bring your current 9410/9420 model and test requirements to a Pacific Power Source applications engineer to confirm.

Will I need to rebuild my test automation when switching from NHR to RGS/GSZ?

The NHR 9410/9420 run on “Enerchron” software over a LAN/SCPI interface. Pacific Power Source systems run SmartSource Suite — a browser-based interface for creating, saving, and running test sequences — and support a broader native interface set (LAN, GPIB, RS232, USB, CAN FD, Modbus, and analog I/O). Most existing SCPI-based test sequences carry over with some re-pointing; bring your specific automation stack to an applications engineer to scope the transition.

Who should I talk to about replacing a 9410 or 9420 before it fails? 

Contact a Pacific Power Source applications engineer with your current model number(s) and power rating(s) — they’ll confirm whether RGS or GSZ is the right fit, map out what changes (if anything) in your test setup and automation, and work out lead times before you’re forced into an unplanned replacement.

Expert Help You Can Trust

Don’t know where to start? That’s what our technical customer service
experts are here for.